Quikly Details:
1. Input: 24VDC/48VDC
2. Output: 220VAC
3. Used for telecom, utility and home use.
4. LCD display
5. High efficiency >85%
6. High frequency
7. Power factor: 0.8
8. Off-grid type
9. Two work mode: DC as mains and AC as mains
10. Standalone type and 19inch rack mount type
Features:
1. DC/AC Inverter with micro-CPU control, an intelligence model product, good designing and reliability are the advantages.
2. This seriers of Inverters are adopted SPWM technology, with the output of stabilized voltage and frequency, pure sine-wave.
3. DC/AC Inverter, with the excellent designing, can be auto switched to bypass on the running state, its easy to maintain and replace the battery without effecting load power supply.
4. In case there is battery voltage high/low or overload, the overload warning shutdown output, when battery voltage recovers normal, battery voltage recovers; Power supply output will auto recovers in 50 seconds after overload off. This function is very suitable for the communication station in which there is no person on duty.
5. Support network communication system, power working state can be monitored by the supervision software.
6. Two dry connectors which can be used for DC input fault checking and AC output problem warning.
7. DC/AC Inverter, with the excellent designing, can be auto switched to bypass on the running state, its easy to maintain and replace the battery without effecting load power supply.
8. This Inverter has 2 working type--- AC power type and DC power type: A. AC power type means the city power supply is main when the city power is normal, when city power is off, inverter comes into work state. B. DC power type means the inverter power supply is main when the city power is normal, when inverter power is off, city power comes into work state automatically.
Specifications:
Rated Capacity(VA) |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
7000 |
8000 |
9000 |
10000 |
Work mode |
DC as mains or AC as mains |
Wave shape |
Pure Sine Wave |
DC Input |
Rated input voltage |
24V/48V |
48V |
Rated input current(A) |
50/24 |
100/48 |
150/72 |
200/96 |
119 |
125 |
143 |
167 |
214 |
238 |
Turn-off voltage range |
24Vdc (20V-30V) 48Vdc(42V-59V) |
Turn-on voltage range |
24Vdc (22V-28V) 48Vdc(45V-57V) |
Anti-noise current irrigation |
≤10% |
|
AC Input |
Allow bypass voltage |
265V-185V(±10V) |
Rated input current(A) |
5.4 |
10.8 |
16.2 |
21.6 |
22.7 |
27 |
37.8 |
36.4 |
43.2 |
54 |
Bypass transfer time(ms) |
≤5ms |
Power factor |
0.8 |
0.7 |
Rated capacity(VA) |
1K |
2K |
3K |
4K |
5K |
6K |
7K |
8K |
9K |
10K |
Rated output power |
800W |
1600W |
2400W |
3200W |
3500W |
4200W |
4900W |
5600W |
6300W |
7000W |
Rated output current |
3.6A |
7.2A |
10.9A |
14.5A |
16A |
19.1A |
22.3A |
25.5 A |
28.6 A |
31.8 A |
Output voltage accuracy |
220 V±1.5% |
Output frequency accuracy |
50Hz±0.1% |
Waveform distortion |
≤3% |
Dynamic Response Time |
0.05 |
Overload |
120%,30s |
Inverter efficiency |
≥85% |
(80% Resistive load) |
Work Condition |
Dielectric Strength |
input & output 1500Vac,1min |
Noise(1m) |
≤40dB |
Ambient temperature |
-25 to 50 degree |
Humidity |
0~95%,Non-condensing |
Altitude(m) |
≤1500 |
Cooling |
Fan cooling |
Interface |
HMI |
LCD+LED display |
Communication interface |
RS232/RS485/RJ45(Choose one) |
Dry contact load output |
2ch /3 ch output ( Choose one) |
Optional |
TCP/IP network interface |
Full protection |
Input under/over voltage; output overload, short circuit protection; AC input high and low voltage |